A novel purification method for high precision measurement of Ni isotopes by double spike MC-ICP-MS | |
Guangliang Wu; Jian-Ming Zhu; Xiangli Wang; Guilin Han; Decan Tan; Shui-Jiong Wang | |
2019 | |
发表期刊 | Journal of Analytical Atomic Spectrometry |
卷号 | 34期号:8页码:1639-1651 |
摘要 | Nickel (Ni) isotopes have been developed as a potential biosignature and proxy for tracing the occurrence of the Great Oxidation Event. However, the precise measurement of Ni isotopes is still hindered by the costly operation, complicated procedures and/or high procedural blanks of the chemical purification schemes. Here, a novel purification scheme, utilizing only dimethylglyoxime (DMG) and acetone as organic reagents, is proposed to separate Ni from samples through a four-step procedure with five chromatographic columns. Steps I, II and III are designed to effectively eliminate major matrix elements, including 99% Fe, Ca, Ti, and Al, 85% Mn, 55% K, even for samples with [Ca]/[Ni] ≈ 4600 and [Mg]/[Ni] ≈ 1900. Step IV utilizes the formation of Ni(DMG)2 complexes in an aqueous medium containing 0.5 M HCl, 95% acetone and 0.1 M DMG, which can remove residual elements such as 45% K; this step avoids the use of Ni-specific resin, which requires careful pH tuning. Steps III and I can be repeated to obtain high-purity Ni. The Ni yield through these four steps is greater than 92%, with a maximum loss of ∼8% occurring in Step II for low-Ni samples. The total procedural blank is 0.4 to 1.2 ng. When double spiking (61Ni–60Ni) is used to correct for instrument mass bias and purification-related isotope fractionation, small sample sizes (600–800 ng) are sufficient for achieving high-precision Ni isotope determination. Nickel isotopes for standards such as SRM 986 and geological reference materials (GRMs) such as BHVO-2, NOD-P-1, and NOD-A were determined on a Nu Plasma III MC-ICP-MS. The long-term reproducibility is 0.05‰ (2SD, n = 134) for pure solution and 0.06‰ (2SD, n = 18) for GRMs, and the average δ60Ni values are in excellent agreement with previous studies. These results show that our new purification method can be applied to various samples. Using this new method, we measured a set of granite, sediment, diamictite and loess samples and preliminarily constrained the δ60Ni of the upper continental crust to be 0.11 ± 0.14‰ (2SD, n = 17). |
收录类别 | SCI |
语种 | 英语 |
文献类型 | 期刊论文 |
条目标识符 | http://ir.gyig.ac.cn/handle/42920512-1/10858 |
专题 | 环境地球化学国家重点实验室 |
作者单位 | 1.Nickel (Ni) isotopes have been developed as a potential biosignature and proxy for tracing the occurrence of the Great Oxidation Event. However, the precise measurement of Ni isotopes is still hindered by the costly operation, complicated procedures and/or 2.Department of Marine Sciences, University of South Alabama, Mobile, AL 36688, USA 3.Dauphin Island Sea Lab, Dauphin Island, AL 36528, USA 4.State Key Laboratory of Environmental Geochemistry, Institute of Geochemistry, CAS, Guiyang, 550081, China |
推荐引用方式 GB/T 7714 | Guangliang Wu; Jian-Ming Zhu;Xiangli Wang;Guilin Han;Decan Tan;Shui-Jiong Wang. A novel purification method for high precision measurement of Ni isotopes by double spike MC-ICP-MS[J]. Journal of Analytical Atomic Spectrometry,2019,34(8):1639-1651. |
APA | Guangliang Wu; Jian-Ming Zhu;Xiangli Wang;Guilin Han;Decan Tan;Shui-Jiong Wang.(2019).A novel purification method for high precision measurement of Ni isotopes by double spike MC-ICP-MS.Journal of Analytical Atomic Spectrometry,34(8),1639-1651. |
MLA | Guangliang Wu; Jian-Ming Zhu;Xiangli Wang;Guilin Han;Decan Tan;Shui-Jiong Wang."A novel purification method for high precision measurement of Ni isotopes by double spike MC-ICP-MS".Journal of Analytical Atomic Spectrometry 34.8(2019):1639-1651. |
条目包含的文件 | 下载所有文件 | |||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
A novel purification(1095KB) | 期刊论文 | 作者接受稿 | 开放获取 | CC BY-NC-SA | 浏览 下载 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论