GYIG OpenIR  > 环境地球化学国家重点实验室
An improved method of Cr purification for high precision measurement of Cr isotopes by double spike MC-ICP-MS
Jian-Ming Zhu;  Guangliang Wu;  Xiangli Wang;  Guilin Han;  Lixin Zhang
2018
发表期刊Journal of Analytical Atomic Spectrometry
卷号33期号:5页码:809-821
摘要

Chromium (Cr) isotopes have been used to trace pollution processes and reconstruct paleo-redox conditions. However, the precise determination of Cr isotopes is still challenged by difficulties in purifying Cr from samples with low Cr and high matrix content. Here, we developed an improved, flexible and easily operated three-step chromatographic procedure to separate Cr from high-matrix samples. A continuous, two-stage column (Step I) filled with 2 mL cation resin AG50W-X8 (200-400 m) and 2 mL anion resin AG1-X8 resin (100-200 m), followed by Step II, with 1 mL of AG1-X8 resin (200-400 m), was used to remove at least 99% of Ca, Fe, and Ti, and >90% of V and most other matrix elements, even for samples with Fe/Cr approximate to 6000 and Ti/Cr approximate to 1000. The recovery of Cr in both Step I and Step II can reach nearly 100%. Step III utilizes 2 mL AG1-X8 (100-200 m) combined with an (NH4)(2)S2O8 oxidant to remove residual matrix elements and achieve high-purity Cr. The total yield of Cr through our three-step procedure is greater than 80% even for low-Cr (2.6 g kg(-1)) samples. A relatively small sample amount (300-600 ng Cr) is enough to achieve high p mu recision Cr isotope measurement due to a low procedural blank (<1 ng). Chromium isotopes in geological reference materials (BHVO-2, JDo-1, JP-1, etc.) were measured on a Neptune Plus MC-ICP-MS. The long-term external precision is 0.06 parts per thousand (2SD), and the delta Cr-53 values are in great agreement with previously reported values. The delta Cr-53 of the upper continental crust is estimated to be -0.10 +/- 0.10 parts per thousand using a suite of granite, diamictite, sediment and loess samples. Both plants and human hair are similar to 0.1 parts per thousand heavier than the upper continental crust. Tests show that our improved purification procedure is applicable to various geological and environmental samples.

收录类别SCI
语种英语
文献类型期刊论文
条目标识符http://ir.gyig.ac.cn/handle/42920512-1/8754
专题环境地球化学国家重点实验室
作者单位1.State Key Laboratory of Geological Processes and Mineral Resources, China University of Geosciences(Beijing), Beijing 100083, China
2.State Key Laboratory of Geological Processes and Mineral Resources, China University of Geosciences(Beijing), Beijing 100083, China
3.Department of Marine Sciences, University of South Alabama, Mobile, AL 36688, USA
4.Dauphin Island Sea Lab, Dauphin Island, AL 36528, USA
推荐引用方式
GB/T 7714
Jian-Ming Zhu;Guangliang Wu;Xiangli Wang;Guilin Han;Lixin Zhang. An improved method of Cr purification for high precision measurement of Cr isotopes by double spike MC-ICP-MS[J]. Journal of Analytical Atomic Spectrometry,2018,33(5):809-821.
APA Jian-Ming Zhu;Guangliang Wu;Xiangli Wang;Guilin Han;Lixin Zhang.(2018).An improved method of Cr purification for high precision measurement of Cr isotopes by double spike MC-ICP-MS.Journal of Analytical Atomic Spectrometry,33(5),809-821.
MLA Jian-Ming Zhu;Guangliang Wu;Xiangli Wang;Guilin Han;Lixin Zhang."An improved method of Cr purification for high precision measurement of Cr isotopes by double spike MC-ICP-MS".Journal of Analytical Atomic Spectrometry 33.5(2018):809-821.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
An improved method o(1127KB)期刊论文作者接受稿开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Jian-Ming Zhu;Guangliang Wu;Xiangli Wang;Guilin Han;Lixin Zhang]的文章
百度学术
百度学术中相似的文章
[Jian-Ming Zhu;Guangliang Wu;Xiangli Wang;Guilin Han;Lixin Zhang]的文章
必应学术
必应学术中相似的文章
[Jian-Ming Zhu;Guangliang Wu;Xiangli Wang;Guilin Han;Lixin Zhang]的文章
相关权益政策
暂无数据
收藏/分享
文件名: An improved method of Cr purification for high precision measurement of Cr isotopes by double spike MC-ICP-MS——1.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。